Sales contact : +91 83205 65287
Sales email : [email protected]
Tender Bidding Website covers all Tenders for Alluminium Conductor Cable – Including Alluminium Conductor Cable Government Tenders, e Tender Alluminium Conductor Cable, Alluminium Conductor Cable Tenders and Private Tenders. There is no shortage of business opportunities from the largest Alluminium Conductor Cable Tender Database.
Our website allows you to find Alluminium Conductor Cable tenders online quickly and easily. Subscribers can also opt to receive daily tender alerts through email from TenderBidding.com to guarantee they don't miss out on any opportunities.
Gem Bids For 1 Core X 1000 Sqmm Pvc 1a1 Power Single Core 630 Sq.mm Xlpe Aluminium Copper 2 Corex2.5 Sqmm Copper , Size 3 C X 16 Sq. Mm. Copper 4 Corex2.5 Mm2 Copper 4 Corex4 Sqmm Armoured Copper 4 Corex10 Sqmm 2 Core X 4 Sq.mm, Xlpe , Armored Copper 1 Core X 25 Mm2 Copper 1 Cx50 Sqmm 1100 Volts 2 Core X 2.5 Mm2 3 Core X 2.5 Mm2 3c X 95 Sqmm Pvc/al 650/1100v Frls Size 3 Corex185 Mm2 3 Core X 400 Mm2 Allum. 3 Core X 300 Mm2 Xlpe 3 Core X 10 Mm2 Armoured 3 Corex150 Sqmm Lt Power , 3 Core X120 Sqmm Stard Aluminium 3c X 50 Sq.mm Aluminium Power 3 1/2 Core X 25 Mm2 L.t.pvc 3.1/2 Corex35 Sqmm Lt 3.1/2 Corex50 Sqmm Lt 3.1/2 Corex70 Sqmm Lt 3.1/2 Corex95 Sqmm 3.1/2 Corex120 Sqmm 3.1/2 Corex25 Sqmm 3.1/2 Corex16 Mm2 L.t.pvc 4 Corex10 Sqmm 1.1 Kv (armoured) Allum. Size 2 Core X 4 Mm2 L.t.power 3 Core X 35sqmm. Aluminium Pvc 3 Core X 16 Mm2 For 650/1100 Volt 1.1 Kv 01c X 630 Sq. Mm Xlpe-al(a) Frls 7 Core X 1.5 Mm2 Copper Str Control . 3c X 1.5 Mm2, Oa Shielded Armored Copper Control 4cx2.5 Sqmm Copper Control 2 Core X 2.5 Mm2 Copper 7 Core X 2.5 Mm2 Control Copper 10 Core X 2.5 Mm2 Control Copper 12 Core X 2.5 Mm2 Control Copper Control 19 Corex2.5 Sqmm Copper Control 24cx2.5 Sqmm 1100voltsx 3c X 2.5mm2 Copper Control Control ,copper , 1100v, 27 Corex2.5mm2 Copper 3 Core X 2.50 Sqmm Control Copper Control 12 Corex4 Sqmm 2px 0.5 Sqmm Overall Shield Armoured Control 4px 0.5 Sqmm Overall Shield Armoured Control 12px 0.5 Sqmm Overall Shield Armoured Control 2px 0.5 Sqmm Control 4px 0.5 Sqmm Control 8px 0.5 Sqmm Control 12px 0.5 Sqmm Control 4p X 0.5 Mm2,armored Copper 12 Corex2.5 Sqmm Copper Flexible 1 Corex70 Sqmm (440/0.45 Mm) Copper Flexible 1cx95 Sqmm (595/0.45 Mm) 3 Core 10 Sqmm Flexible Annealed Copper Instrumentation 16 Core 8 Pair X 0.5 Sqmm 12 Corex0.5 Sqmm, Instrument Thermocouple Extension 2 X 2 X 0.5 Sqmm 04 Pair, 16 Thermocouple Extension Armoured Xlpe Insulated, 3c X 300 Mm2 3c X185 Sqmm Ty-c Frls 3 Corex150 Sqmm Lt 3 Corex70 Sqmm 2c X 70 Sq Mm Copper size 3 Core X 35 Mm2 Power Size 3c X 10 Mm2 Control Cu Size 2 C X 10 Mm2 Copper Size 3 Core X 4 Mm2 Copper Flex. 1 Core X 50 Mm2 Flat 3 Corex4 Sqmm With Copper 3 Core X 25 Mm2 Pvc Insulated Lt Power 4 Corex16 Sqmm , 2.5 Mm2 Pvc Insulated Copper Of Size 4 Corex6 Sqmm 12 Corex2.5 Mm2 Annealed Tinned Copper Cond 4 Core X 25 Sq. Mm 3 Core X 50 Mm2 Control Trailing 16 Core X 2.5 Sqmm,1.1 Kv Copper 16 Pairx0.5 Sqmm
Supply of Welding Hofr Covering Size In Sq. Mm. 9 5, Rated Current In Amps. At 60% Duty Cycle:438A Min Weight Of 1 Mtrs. Lengths Of Should Be 253.90 Gms. Specifications:The Standard Length Of The Shall Be 50/100 Meters.Isi Marked Aluminium Welding s Covered With General Purpose Hofr Compound Conforming To Is:9857/90Reaffirmed In March 2020 With Amdt. N O.-1.Current Capacity Is At 60% Duty Cycle At 30 Degree Centigrade Ambient Temperatur E. Warranty Period: 30 Months After The Date Of Delivery
Sitc Of 11Kv Indoor Switchboards And Lt 3 Phase 415V Power Distribution Switchboards, 307 11 Kv Vcb Panel 800A As Detailed In Technical Specifications Lt Panel 415V-440V With 03 Nos. 1000A Incoming Regional Supply And 03 Nos. 1000A Incoming Dg Supply And 12 Nos. 400A Outgoing And 04 Nos. 63A Out Going And 02 Nos. 1000A Bus Coupler Sub Lt Panel 415V- 440V With 01 No. 1000A Incoming Regional Supply And 06 Nos 400A Outgoing 240 Sqmm 1.1Kv 3 Core Xlpe Insulated Armoured Dismantling Of Existing Panels And Installation Testing And Commissioning Of Supplied Panels Spares For Supplied Vcb And Acb Panels
Supply Of Led Tube Light Fitting 18 Watt, Led Tube Light 20 Watt, Led Street Light Fitting 40 Or 45 Watt, Led Bulb 12 Watt, Xlpe Armed 3.5 By 50 Sqmm Alu Cond, Led Bulb 9 Watts, Led Bulb 15 Watt, Xlpe Armed 3.5 By 35 Sqmm Alu Cond, Mccb 200 Amp 4 Pole 415 V, Led Bulb 18 Watt, Led Mirror Light 9 Watt, Led Bulb 7 Watt, Mccb 400 Amp 4 Pole 415 V, Chang Over Switch 63 Amp 4 Pole, Mcb 63 A Tpn 4 Pole, Socket 16 Amp, Xlpe Armd 4 By 16 Sqmm Copper , Pvc Tc 4.0 Sqmm, Xlpe Armd 3.5 By 25 Sqmm Copper , Mcb Dp 40 A, Mcb Tpn 63 A, Mccb 320 Amp 4 Pole 415 V, Mcb 40 Amp 3 Pole Tp, Fan Regulator, Isolator Tp 415V 63 Amp, Electric Exhaust Fan 450 Mm, Electric Exhaust Fan 380 Mm Or 300 Mm, Chock Elect 36 Watt, Mcb 16 Amp Sp, Isolator 4 Way 63 Amp, Mcb 32 Amp 3 Pole Tp, Pvc Copper Wire S C 1.5 Sqmm, Mcb Sp 10 Amp, Switch Piano Type 16 Amp, Mcb 32 Amp Spn, Chock Elect 40 Watt, Socket P T 5 Or 6 Amp, Mcb 40 Amp Sp, Mcb 10 Amp 2 Pole, Pvc Aluminium 6 Sqmm T C, Switch P T 5 Or 6 Amp, Pvc Copper Wire S C 6 Sqmm, Xlpe Armed 3.5 By 70 Sqmm Copper , Pvc Copper 4 Sqmm Sc, Tape Insulation 25Mm By 25 Mtr, Mcb 20 Amp Spn, Condensor 2.5 Mfd, Multi Purpose Socket 6 Or 16 Amp, Xlpe Armd 2 By 10 Sqmm Copper , Electronic Ballast Suitable For Ftl 36 Or 40 Watt, Mcb 6 Amp Sp, Door Bell, Switch 15 Amp, Mcb 20 Amp Sp, Angle Holder, Call Bell, Pvc Copper 2.5 Sqmm Sc, Ss Combination 5 Or 15 Amp, Pvc Copper 10Sqmm Sc, Tape Insulation 20Mm By 25 Mtr, Mcb 16 Amp Spn, Plug Three Pin 16 Amp, Celling Rose, Mcb 25 Amp Sp, Flexible 40 Or 0.0076 Twin Core, Bell Push 6 Amp
Supply of Welding Hofr Covering Size In Sq. Mm. 95, Rated Current In Amps. At 60% Duty Cycle:438A Min Weight Of 1 Mtrs. Lengts Of Cabl E Should Be 253.90 Gms. Specifications:The Standard Length Of The Shall Be 50/100 Meters.Isi Marked Aluminium Welding s Covered With General Purpose Hofr Compound Conforming To Is:9857/90Reaffirmed In 2005 With Am Dt. No.-1.Current Capacity Is At 60% Duty Cycle At 30 Degree Centigrade Ambient Tem Perature. Warranty Period: 30 Months After The Date Of Delivery
Supply of Providing Power Supply To Museum And Patient Accommodation Building, 651 Digging Of Trench Supply And Fixing Of Flooring Mount Supply And Laying Of Five Bar Size Inch Dia Dwc Pipe Supply And Laying Of Supply And Fixing Of Heavy Duty