Sales contact :  +91 83205 65287

Sales email :  [email protected]

Ac Capacitor Tenders | Latest Tenders for Ac Capacitor

Total 442 Ac Capacitor tenders found

Tender Bidding Website covers all Tenders for Ac Capacitor – Including Ac Capacitor Government Tenders, e Tender Ac Capacitor, Ac Capacitor Tenders and Private Tenders. There is no shortage of business opportunities from the largest Ac Capacitor Tender Database.

Our website allows you to find Ac Capacitor tenders online quickly and easily. Subscribers can also opt to receive daily tender alerts through email from TenderBidding.com to guarantee they don't miss out on any opportunities.


#TBD : 31751189
17 Days Left
Railway Transport
Telangana
Ref. Document
Due on : 04 Jun, 2024

Supply of Oil Filled 20Mfd Capitor 415V +/- 10% Suitable For Radiator Fan Motor Of Conventional Emu M Otor Cohes With Box Fitted As Per Dy.Cee/Ws/Kgps Drg No.Dy Cee/Ws/Kgp/Emu/1415.Type-1. Make: Sun Ny/Icar/Advance Or Equivalent. Warranty Period: 30 Months After The Date Of Delivery

View

Bidding

Gem Registration

Download

#TBD : 31740087
6 Days Left
Steel And Iron Product
Orissa
Ref. Document
Due on : 24 May, 2024

Supply Of Ups Spares - Pca-Smd B.Boost Ctrl Card, Bp5142, Vertiv, Pca-Manis Fb And Sync Trafo Card, Bp5050, Pca-Assembly, Pn000000bp5068, Vertiv, Fan, Centrifugal, Pn0000000e5009, Vertiv, Capitor, , 100Mf, 370V, Igbt, Dual Module, 242A, 1200V, Q5059, Vertiv, Scr Diode Module, 0000000D0257, Vertiv, Capitor, 4700Uf, 450Vdc, C5056, Vertiv, Igbt, Dual Module, 190A, 1200V, Q5043, Vertiv, Capitor, Al Elec, 4700Mfd, 350V, Pn-C5040

View

Bidding

Gem Registration

Download

#TBD : 31727218
16 Days Left
Telecommunication Services And Equipments
Maharashtra
22.75 Lacs
Due on : 03 Jun, 2024

Repairs And Misc Works Of Split In Various Bas Of Ed - Attending Complaint And Wet Servicing Of Unit Upto 50 Kms, Attending Complaint And Wet Servicing Of Unit Upto 51 To 100 Kms, Attending Complaint And Wet Servicing Of Unit Above 101 Kms, Replement Of Starting Capitor 80 To 100 Mfd Of Unit, Replement Of Running Capitor 36 To 50 Mfd Of Unit, Replement Of Capitor For Condenser Fan 4 To 6 Mfd Of Unit, Replement Of Sensor For Split Unit, Replement Of Conttor Relay For Split Outdoor Unit, Replement Of Starting Relay Of Unit, Replement Of Thermostat Of Unit, Replement Of Selector Switch Of Unit, Replement Of Blade For Condensor Of Window Or Split Unit, Replement Of Blower Assembly For Split Unit Without Motor, Replement Of Pcb For Conventional Split Indoor Unit Of 1.5 Tr, Replement Of Pcb For Outdoor Unit Of Invertor Type Split , Replement Of Pcb For Indoor Unit Of Invertor Type Split , Replement Of 1.5Tr Or 2Tr Split Remote, Replement Of Fan Motor For Condenser Unit Of Conventional 1.5 Or 2 Tr Of , Replement Of Blower Motor For Indoor Unit Of 1.5Tr Or 2 Tr Of Split , Replement Of 20Mm Dia Flexible Pvc Pipe For Drain Water Connection Of , Charging Of R22 Or R32 Or R134 Or R410 Refrigerant Gas Upto The Optimum Working Pressure Suitable For 1.5 Or 2Tr Alongwith Attending Leakage, Replement Of Cond Coil Manuftured With Cu Tube And Al Fins With Antirust Coating And Blue Fin Hydrophilic Coating For S Incl. Credit Of Old Coil, Dismantling Of Window Unit Alongwith Casing Ms Supporting Frame, Dismantling Of Split Or High Sensible Incl. Id And Od Unit Aw All c. Pump Down Of Gas And Keeping All Dismantled Material At Safe Location, Transportation Of Dismantled 2 No. Units Upto 20 Km With All cessories Incl. Hiring Of Vehicle, Manpower, Transportation Of Dismantled 2 No. Units From 21 Km To 50 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 3No. To 5 No. Units From 21 Km To 50 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 2 No. Units From 51 Km To 100 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 3No. To 5 No. Units From 51 Km To 100 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 3No. To 5 No. Units From 100 Km Upto 200 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Itc Of 1.5 Or 2Tr Window Unit With Properly Finshing And Minor Civil Work, Itc Of Wall Mounting Type 1.5 Or 2Tr Split Unit With Properly Finishing And Minor Civil Work, Itc Of 2X1.5 Tr High Sensible Unit With Properly Finishing And Minor Civil Work, S And F Of 1 By 4 Inch Copper Refrigeration Pipe, S And F Of 3 By 8 Inch Copper Refrigeration Pipe, S And F Of 1 By 2 Inch Copper Refrigeration Pipe, S And F Of 5 By 8 Inch Copper Refrigeration Pipe, P And W Of Expanded Polyethylene Foam Tube Insulation For 1 By 4 Inch Copper Refrigeration Pipe, P And W Of Expanded Polyethylene Foam Tube Insulation For 3 By 8 Inch Copper Refrigeration Pipe, P And W Of Expanded Polyethylene Foam Tube Insulation For 1 By 2 Inch Copper Refrigeration Pipe, P And W Of Expanded Polyethylene Foam Tube Insulation For 5 By 8 Inch Copper Refrigeration Pipe, S And F Of Prefabricated Powder Coated Heavy Duty Iron Stand Having Projection Arm Minimum 600 Mm, S And Fabrication Of M.S. Frame Made Out Of Various M.S. Sections Incl. Hardwares Finishing, Painting, Minor Civil Work Etc, P And F Of 12Mm Thick Prelaminated Particle Board With Decorative Lamination On Both Side Flat Pressed 3 Layer Or Graded Wood Particle Board, S And L Of 4 X 1.5 Sq Mm Copper Conductor Unarmoured Cable Of 1.1 Kv Grade Isi Mark, S And L Of 3 X 2.5 Sq Mm Copper Conductor Unarmoured Cable Of 1.1 Kv Grade Isi Mark, S And F Of 20 Mm Dia Heavy Gauge Rigid Upvc Pipe Of Isi Mark, S And F Of 25 Mm Dia Heavy Gauge Rigid Upvc Pipe Of Isi Mark, S And L Of 3 X 2.5 Sq Mm Copper Conductor Armoured Cable Of 1.1 Kv Grade Isi Mark, S And M End Termination With Brass Compression Gland For 3 X 2.5 Sq Mm Size Of Pvc Insulated Pvc Sheathed Or Xlpe Cu Condr Armd Cable, S And F Of 2 Way Spn Mcb Db, S And F Of 5A To 32A 10Ka C Curve Sp Mcb, S And F Of 5A To 32A 10Ka C Curve Spn Mcb, S And F Microprocessor Based Energy Saver Unit For Controlling The Operation Of 2 A.C. Unit Having Safety Protection, Disply, Auto, Manual Mode, Repairing Of Faulty Controller Of Unit, Sand F Of Electronic Voltage Stabilizer Suitable For Operation On 130Volt To 290 Volt For 1.5Tr Unit, Installation Of Spn Or Tpn Mcb Db, Fixing Of Sp Or Spn Or Dp Or Tp Or Tpn Or Fp Mcb, Fixing Of Outdoor Condensor Stand, Fixing Of Both Size Of Refregerent Piping But Without Heatlone Tube, Laying Of 2 Or 3 Or 4 Core Copper Conductor Armoured Or Unrmoured Cable Up To Size 4 Sq Mm., Fixing Of Cyclic Timer, Fixing Of 20Mm Or 25Mm Dia Drain Water Pvc Pipe

View

Bidding

Gem Registration

Download

#TBD : 31728567
16 Days Left
Railway Transport
Karnataka
Ref. Document
Due on : 03 Jun, 2024

Supply of 3 Kvar Metalized Polypropylene Gas Filled, Wavy Cut Three Phase Self Hea Ling Type Capitors. Rated At 480V, 50Hz, Rated Current 1.2 Amps Capitor Should H Ave Discharge Resistor And Over Pressure Disconnection As Per Rdso Modification Sheet No. Rdso/Pe/Ms//0054-2014 Rev-1 And Confirming To Is: 13340 With Isi Mark Suitabl E For Capitor Bank Of Lhb Coh. Make: M/S Epcos Or M/S Vishay Or Any Other Eq Uivalent Capitor Confirming To Is: 13340 With Isi Mark And Having Property As Defin Ed In Table-1 cording To Rdso/Pe/Ms//0054-2011 Rev.0 Firm Shall Submit Complete T Ype Test Report As Per Is 13340 Along With Latest Isi Certification Warranty Period: 30 M Onths After The Date Of Delivery

View

Bidding

Gem Registration

Download

#TBD : 31721829
2 Days Left
Railway Transport
West Bengal
Ref. Document
Due on : 20 May, 2024

Supply of 1000 Fixed Capitors Fixed Capitor For Single Phase Electric Fan As Per Is 1709:1984 Q3

View

Bidding

Gem Registration

Download

#TBD : 31719872
0 Days Left
Security Services
Bihar
Ref. Document
Due on : 16 May, 2024

Supply Of Piano Type Non Modular Domestic Fan Regulator As Per Is 11037 Q3, Piano Type Non Modular Electrical Switch Socket Combination As Per Is 3854 And Is 1293 Q3, Electrical Plug Q3, Fixed Capitors Fixed Capitor For Single Phase Electric Fan As Per Is 1709:1984 Q3, Ceiling Rose - Is 371 Q3, Non - Modular Piano Type Domestic Electrical Switches As Per Is 3854 Q3, Modular Electrical Enclosure Switch Board Boxes For Modular Type cessories Q3

View

Bidding

Gem Registration

Download

#TBD : 31720625
16 Days Left
Telecommunication Services And Equipments
Maharashtra
Ref. Document
Due on : 03 Jun, 2024

Rate Contrt For Call Basis Repairs And Miscellaneous Works Of Split In Various Bas - Attending Complaint And Wet Servicing Of Unit Upto 50 Kms, Attending Complaint And Wet Servicing Of Unit Upto 51 To 100 Kms, Attending Complaint And Wet Servicing Of Unit Above 101 Kms, Replement Of Starting Capitor 80 To 100 Mfd Of Unit, Replement Of Running Capitor 36 To 50 Mfd Of Unit, Replement Of Capitor For Condenser Fan 4 To 6 Mfd Of Unit, Replement Of Sensor For Split Unit, Replement Of Conttor Relay For Split Outdoor Unit, Replement Of Starting Relay Of Unit, Replement Of Thermostat Of Unit, Replement Of Selector Switch Of Unit, Replement Of Blade For Condensor Of Window Or Split Unit, Replement Of Blower Assembly For Split Unit Without Motor, Replement Of Pcb For Conventional Split Indoor Unit Of 1.5 Tr, Replement Of Pcb For Outdoor Unit Of Invertor Type Split , Replement Of Pcb For Indoor Unit Of Invertor Type Split , Replement Of 1.5Tr Or 2Tr Split Remote, Replement Of Fan Motor For Condenser Unit Of Conventional 1.5 Or 2 Tr Of , Replement Of Blower Motor For Indoor Unit Of 1.5Tr Or 2 Tr Of Split , Replement Of 20Mm Dia Flexible Pvc Pipe For Drain Water Connection Of , Charging Of R22 Or R32 Or R134 Or R410 Refrigerant Gas Upto The Optimum Working Pressure Suitable For 1.5 Or 2Tr Alongwith Attending Leakage, Replement Of Cond Coil Manuftured With Cu Tube And Al Fins With Antirust Coating And Blue Fin Hydrophilic Coating For S Incl. Credit Of Old Coil, Dismantling Of Window Unit Alongwith Casing Ms Supporting Frame, Dismantling Of Split Or High Sensible Incl. Id And Od Unit Aw All c. Pump Down Of Gas And Keeping All Dismantled Material At Safe Location, Transportation Of Dismantled 2 No. Units Upto 20 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 3No. To 5 No. Units Up Transportation Of Dismantled 3No. To 5 No. Units Upto 20 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 2 No. Units From 21 Km To 50 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 3No. To 5 No. Units From 21 Km To 50 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 2 No. Units From 51 Km To 100 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 3No. To 5 No. Units From 51 Km To 100 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Transportation Of Dismantled 3No. To 5 No. Units From 100 Km Upto 200 Km With All cessories Incl. Hiring Of Vehicle, Manpower Etc, Itc Of 1.5 Or 2Tr Window Unit With Properly Finshing And Minor Civil Work, Itc Of Wall Mounting Type 1.5 Or 2Tr Split Unit With Properly Finishing And Minor Civil Work, Itc Of 2X1.5 Tr High Sensible Unit With Properly Finishing And Minor Civil Work, S And F Of 1 By 4 Inch Copper Refrigeration Pipe, S And F Of 3 By 8 Inch Copper Refrigeration Pipe, S And F Of 1 By 2 Inch Copper Refrigeration Pipe, S And F Of 5 By 8 Inch Copper Refrigeration Pipe, P And W Of Expanded Polyethylene Foam Tube Insulation For 1 By 4 Inch Copper Refrigeration Pipe, P And W Of Expanded Polyethylene Foam Tube Insulation For 3 By 8 Inch Copper Refrigeration Pipe, P And W Of Expanded Polyethylene Foam Tube Insulation For 1 By 2 Inch Copper Refrigeration Pipe, P And W Of Expanded Polyethylene Foam Tube Insulation For 5 By 8 Inch Copper Refrigeration Pipe, S And F Of Prefabricated Powder Coated Heavy Duty Iron Stand Having Projection Arm Minimum 600 Mm, S And Fabrication Of M.S. Frame Made Out Of Various M.S. Sections Incl. Hardwares Finishing, Painting, Minor Civil Work Etc, P And F Of 12Mm Thick Prelaminated Particle Board With Decorative Lamination On Both Side Flat Pressed 3 Layer Or Graded Wood Particle Board, S And L Of 4 X 1.5 Sq Mm Copper Conductor Unarmoured Cable Of 1.1 Kv Grade Isi Mark, S And L Of 3 X 2.5 Sq Mm Copper Conductor Unarmoured Cable Of 1.1 Kv Grade Isi Mark, S And F Of 20 Mm Dia Heavy Gauge Rigid Upvc Pipe Of Isi Mark, S And F Of 25 Mm Dia Heavy Gauge Rigid Upvc Pipe Of Isi Mark, S And L Of 3 X 2.5 Sq Mm Copper Conductor Armoured Cable Of 1.1 Kv Grade Isi Mark, S And M End Termination With Brass Compression Gland For 3 X 2.5 Sq Mm Size Of Pvc Insulated Pvc Sheathed Or Xlpe Cu Condr Armd Cable, S And F Of 2 Way Spn Mcb Db, S And F Of 5A To 32A 10Ka C Curve Sp Mcb, S And F Of 5A To 32A 10Ka C Curve Spn Mcb, S And F Microprocessor Based Energy Saver Unit For Controlling The Operation Of 2 A.C. Unit Having Safety Protection, Disply, Auto, Manual Mode, Repairing Of Faulty Controller Of Unit, Sand F Of Electronic Voltage Stabilizer Suitable For Operation On 130Volt To 290 Volt For 1.5Tr Unit, Installation Of Spn Or Tpn Mcb Db, Fixing Of Sp Or Spn Or Dp Or Tp Or Tpn Or Fp Mcb, Fixing Of Outdoor Condensor Stand, Fixing Of Both Size Of Refregerent Piping But Without Heatlone Tube, Laying Of 2 Or 3 Or 4 Core Copper Conductor Armoured Or Unrmoured Cable Up To Size 4 Sq Mm., Fixing Of Cyclic Timer, Fixing Of 20Mm Or 25Mm Dia Drain Water Pvc Pipe

View

Bidding

Gem Registration

Download

#TBD : 31715370
10 Days Left
Power
Rajasthan
Ref. Document
Due on : 28 May, 2024

Supply of 720 Fixed Capitors Fixed Capitor For Single Phase Electric Fan As Per Is 1709:1984 Q3

View

Bidding

Gem Registration

Download

#TBD : 31716451
2 Days Left
Railway Transport
Madhya Pradesh
Ref. Document
Due on : 20 May, 2024

Supply & Testing Of 3 Pole Conttors For Capitor Switching 3P Operated Type Ua26-30- 10R A Of Abb Design -Main Poles And Auxiliary Contts : 3 Main Poles With Inbuilt Surge Protection And 1 Auxiliary Co Ntt Having No & Nc -Control Circuit : Operated With Laminated Magnet Circuit, The Ua..Ra Series Conttors Fitted With A Special Front Mounted Block Which Ensures The Serial Insertion Of 3 Damping Resistors Into The Circuit T O Limit The Current Peak On Energization Of The Capitor Bank As Per Iec : 60947-4-1 Suitable Use In Existing Apf C Panel. Make : Abb Ua26-30- 10Ra 220-230V 50Hz Or Make : L&T, Schneider, Siemens, Legrand Or Similar Note : A Sample To Be Got Approval Before Bulk Supply. Warranty Period: 30 Months After The Date Of Delivery

View

Bidding

Gem Registration

Download

#TBD : 31691937
0 Days Left
Railway Transport
Tamil Nadu
Ref. Document
Due on : 13 May, 2024

Supply of Damping Board Assembly With Damping Capitor 25Mfd/ 500Volts, Confirming To Is:13648, To Make M/S.Icar-Italy Model Msr 25D-22-50 22 Mfd, 550 Volts Or To M/S Yash Capitor / Nasik Model Ye-0 01 25 Mfd, 660V Or To M/S Advance Mysore Type Aspr-15 25 Mfd, 660V Only., Damping Board Similar To M/S Usha Drg. No.3.89.92405 Rev. 0 Or To M/S Hirect Drg. No. 3Tr-2112. Warranty Period: 30 Months After The Da Te Of Delivery

View

Bidding

Gem Registration

Download